AS 1210 Appendix N: what it actually says about nozzle local loads

A clause-by-clause read of AS 1210-2010 Appendix N, N3: the PD 5500 route, the WRC 107 restriction for pierced shells, the mandatory PSIF, the N3.5 stress limits, and where WRC 537 fits.

  • AS 1210 App N
  • N3.5
  • WRC 297
On this page
  1. It is normative, and the body sends you there
  2. Route one: PD 5500 Appendix G, in its entirety (N3.4)
  3. Route two: WRC 297, not 107, for a pierced shell (N3.5)
  4. The pressure stress and its PSIF
  5. The stress limits
  6. Where WRC 537 fits: my reading
  7. What to put in the calc so the reviewer signs it

Clause N3.5 of AS 1210-2010 contains these words: “WRC 107 should not be used for nozzles in shells (i.e. attachments where the shell is pierced)”. Plenty of AS 1210 nozzle calcs run WRC 107, or its 2010 reprint WRC 537, on a nozzle in a cylindrical shell and stop there. This post goes through Appendix N clause N3 as printed in AS 1210-2010 incorporating Amendments 1 and 2, neither of which touched Appendix N. Page references are to the printed pages, 398 to 401.

It is normative, and the body sends you there

The heading reads “(Normative)”, and the Preface says “A ‘normative’ appendix is an integral part of this Standard”. The body points there in mandatory terms too. Clause 3.19.10.4: “Design of nozzles against external loads shall be according to Appendix N.” Table 1.6 item 3.4 makes local load assessment “Required (See Appendix N)” for Classes 1H, 2H, 1S and 2S, and “Not typically required (See Appendix N)” for Classes 1, 2A, 2B and 3.

Read the verbs as well. Clause 1.8.27 makes “shall” mandatory and Clause 1.8.28 makes “should” “a recommendation”. The 107 restriction is a “should”. My reviewing rule: a calc that breaks a “shall” doesn’t comply. A calc that departs from a “should” needs a written reason, and one that departs silently goes back.

N3.3 sends FEA to Appendices I and H, and notes that the Appendix N requirements “are unsuitable for use with FEA”. Don’t grade a finite element result against the N3.5 limits.

Route one: PD 5500 Appendix G, in its entirety (N3.4)

N3.4 allows PD 5500 Appendix G “provided it is used in its entirety, and provided that the specified limitations are complied with”, and closes with “Stress limits shall be as set out in PD 5500.” You can’t take PD 5500 stresses and grade them against N3.5. Extrapolating the curves is allowed “provided that such extrapolation is conservative”.

Pads at a nozzle use the combined shell and pad thickness for the pressure stress at the nozzle edge, “or the insert plate thickness provided that full penetration welds are used for the connection”. A plate under a solid attachment is “not considered to carry any pressure stress”. Where an attachment is welded only to the pad, the pad “must be of adequate thickness to transfer any load to its outer edges without considering any benefit from the shell”, and the note adds: “It cannot be assumed that the combined thickness of the shell and pad share the load.”

Route two: WRC 297, not 107, for a pierced shell (N3.5)

The opening paragraph of N3.5, in full:

“The WRC methods shall not be used beyond their limits of applicability (such as diameter to thickness ratios). WRC 107 should not be used for nozzles in shells (i.e. attachments where the shell is pierced), but is suitable for non-pressurized attachments, and for nozzles in ends. WRC 297 may be used for pressurized nozzles in shells.”

WRC 297 gives the physical reason. Its Appendix C says the 107 curves come from Bijlaard’s solution “for the case of a uniform, unpenetrated cylindrical shell subjected to a distributed load applied over a rectangular area.” A nozzle sits in a hole. 297 models the two intersecting cylinders.

N3.5 also gives some relief on 297, which it notes “is generally considered to be overly conservative in the calculation of stresses in the nozzle wall”. You may instead take the maximum tensile stress in the nozzle wall from pressure plus the local combined bending moment, and compare it against “a maximum of 1.2 × f for the nozzle at design temperature”.

The pressure stress and its PSIF

The first note to N3.5 starts from the fact that the WRC 107/297 methods “do not consider the effects of any pressure stress intensification factor (PSIF) that may apply at an opening.” The pressure stress in the shell or head is calculated, multiplied by a PSIF and added algebraically to the external load stress at the nozzle OD. The clause text makes this mandatory: “This stress shall be multiplied by the calculated PSIF and added to the stress due to the external load.”

The note after it rules out the old shortcuts. Adding “pressure thrust” to the radial load, or hoop stress to the calculated membrane stress, is “not considered appropriate for use with current design strengths.”

The PSIF may come from “PD 5500, WRC 368, ASME BPV-VIII-2 (2004) Table AD560.7, or another suitable method that is agreed between the parties concerned.” The choice of source is itself a matter for agreement, and the notes warn that “PD 5500 appears to be the least conservative method for determining the PSIF.” An allowed refinement applies the PD 5500 factor only to the circumferential membrane pressure stress in the longitudinal plane, and to the longitudinal membrane pressure stress in the circumferential plane.

Pads follow the N3.4 pattern: combined shell and pad thickness at the nozzle edge, or the insert plate thickness. Plates under solid attachments carry no pressure stress “and thus do not contribute to a reduction in the shell stresses locally.” For the external load side of a padded nozzle, see the reinforcement pads post.

The stress limits

N3.5 ends with this list, quoted exactly:

  • (a) “The maximum calculated membrane stress shall not exceed 1.2 × f.”
  • (b) “The maximum calculated shear stress shall not exceed 0.5 × f.”
  • (c) “The maximum calculated local membrane + bending stress shall not exceed the following:”
    • (i) “1.5 × ReT at the edge of a nozzle.”
    • (ii) “1.3 × ReT at the edge of a solid attachment or edge of a reinforcing pad, where pads are within a radius of 0.5 × (RT)0.5 from the OD of the nozzle or 0.15 of the shell circumference from the nozzle centreline.”
    • (iii) “1.5 × f at the edge of a solid attachment or edge of a reinforcing pad, where pads are outside a radius of 0.5 × (RT)0.5 from the OD of the nozzle or 0.15 of the shell circumference from the nozzle centreline.”
  • (d) “Compressive membrane stresses shall not exceed 0.9 × ReT.”

f is the design tensile strength at design temperature (Clause 3.3.1, values from Table B1). ReT is listed in Table 1.10 as the specified minimum yield strength at temperature T, and Appendix A2 defines it as the “Specified minimum value of ReL or Rp0.2 (Rp1.0 for austenitic steels) for the grade of material concerned at design temperature T”.

RT is printed with a subscript T and never defined in Appendix N, and Table 1.10 uses T for temperature. I read it as R × T, shell mean radius times shell thickness, so the distance is 0.5√(R·T). √(R·T) is the usual length scale for shell bending. That is my reading, not the standard’s text, so state yours in the calc.

Now compare (ii) and (iii). For Classes 1, 2A, 2B, 3, 1H and 2H below the creep range, Table A1 makes ReT/1.5 one of the ceilings on f, so 1.5 × f does not exceed ReT. A pad edge outside that distance from the nozzle therefore gets a limit at least 23% lower than one inside it (1.0/1.3 = 0.77). The standard doesn’t say why. That is not automatic for the cold-stretched Classes 1S and 2S, whose f comes from Clause L3.3 (Note 2 to Table A1), or for the low-temperature strengths of Clause 3.33.

The distance test is written for pads, measured from a nozzle. The clause does not say how the edge of a solid attachment, which has no nozzle to measure from, is sorted between (ii) and (iii).

Where WRC 537 fits: my reading

This section is my interpretation, not the standard’s text.

AS 1210-2010 was approved on 28 July 2010, and WRC 537 is a 2010 edition. Appendix N names WRC 107, 297 and 368, Appendix R lists the same three, and 537 appears nowhere in the standard.

WRC’s foreword to 537 says what it is: “It is not an update or a revision of 107. It is the 2010 printing of WRC 107.” The cylinder method in 537 §4 plots “The results of Bijlaard’s work”, the same unpenetrated-shell model 297 describes. The N3.5 restriction is about the model, not the cover, so in my reading it applies to 537 §4 exactly as it applies to 107.

Treating 537 as one of the “other manual analytical methods” of N3.6 doesn’t help, because N3.6 requires you to consider “Any assumptions or limitations of the method”.

In practice, on the AS 1210 route:

  • A nozzle in a cylindrical shell gets WRC 297 for the external loads, plus the shell pressure stress times an agreed PSIF, graded against N3.5 (a) to (d).
  • Lugs, clips and trunnions that don’t pierce the shell can stay on 537, with no pressure stress credited to their pads.
  • Nozzles in heads can use the 537 sphere method, since N3.5 allows 107 “for nozzles in ends”, still with the PSIF.
  • Outside 297’s limits, use PD 5500 Appendix G in full, or FEA under Appendix I.

The decision tree post shows how ASME and PD 5500 route the same choice.

What to put in the calc so the reviewer signs it

  • The route by clause, N3.4 or N3.5, with no mixing of PD 5500 stresses and N3.5 limits.
  • For each attachment: pierced or not, shell or head, and the method that follows. If you use 107 or 537 on a pierced cylinder anyway, say why.
  • A check that the geometry is inside the method’s limits of applicability. That one is a “shall”.
  • The design external loads and their source. N2 requires them to be “clearly set out in the design documentation”.
  • The pressure stress: thickness used, PSIF source and the agreement to use it, and whether you used the plane-by-plane refinement. No pressure thrust in the radial load.
  • The limit table with f and ReT values and their sources, (c)(ii) or (c)(iii) for each pad or attachment edge, and your reading of RT.
  • The compressive membrane check, (d). It is the easiest one to forget.

If you want a second set of numbers, the nozzle tool grades WRC results against the AS 1210-2010 Appendix N, Clause N3.5 local-load limits, with design strengths from Table B1. It does not do AS 1210 shell, head or opening design, and running a check needs no login. One thing to know against the reading above: on every code, AS 1210 included, the tool takes its shell rows from WRC 537 and its nozzle-wall rows from WRC 297. Treat the 297 rows as the N3.5 route and the 537 shell rows as a comparison. The worked example runs one nozzle that way, start to finish.

If you were on ME-001 for the 2010 edition, or know someone who was, I’d like to know two things: what RT was meant to be, and why the far pad-edge limit is the tighter one.

Keep reading

All posts